Basics
To establish short-distance connections or as a backup for an existing fiber connection, systems without an integrated backup are also suitable. These systems can be used for Ethernet or Fast Ethernet as well as for ATM backbone connections.
|
|
 |
Technical Data |
 |
|
|
|
 |
|
|
 |
Laser-LINK 800/2000 |
 |
|
|
|
 |
|
|
 |
Laser-LINK 300/155 |
 |
|
|
|
 |
|
|
 |
Laser-LINK XX/155 |
 |
|
|
|
 |
|
|
 |
Unit |
 |
|
|
|
| Transmission |
 |
 |
 |
 |
 |
 |
|
|
|
|
| Range: |
 |
50..2000 |
50..300 |
300..2000 |
m |
| Capacity: |
 |
2..43 |
20..155 |
20..155 |
Mbps |
| Bit error ratio: |
 |
10 -9 |
10 -12 |
10 -12 |
- |
| Optical performance |
 |
 |
 |
 |
 |
 |
|
|
|
|
| Sender: |
 |
Laser |
Laser |
Laser |
- |
| Launched power: |
 |
1..3 |
10 |
10 |
mW |
| Laser class: |
 |
III B |
III B |
III B |
- |
| Divergence: |
 |
<5 / <3 |
<5 |
<3 / <1 |
mrad |
| Dynamic range: |
 |
>30 |
>30 |
>30 |
dB |
| Interface |
 |
Multimode-LWL |
Multimode-LWL |
Multimode-LWL |
- |
| Connector |
 |
2·FSMA |
2·ST |
2·ST |
|
| Dimensions: |
 |
50..62,5/125 |
50..62,5/125 |
50..62,5/125 |
µm |
| Wavelength (RX): |
 |
780..900 |
1270..1350 |
1270..1350 |
nm |
| Wavelength (TX): |
 |
850 |
1310 |
1310 |
nm |
| Power in 50/125: |
 |
-18 |
-18 |
-19 |
dBm |
| Receiving level |
 |
 |
 |
 |
 |
 |
|
|
|
|
| (max./min.): |
 |
-30/-13 |
-30/-15 |
-30/-15 |
dBm |
| Temperature range: |
 |
-20..+50 |
-20..+50 |
-20..+50 |
°C |
| Miscellaneous |
 |
 |
 |
 |
 |
 |
|
|
|
|
| Power supply: |
 |
230, 15 |
230, 16 |
230, 20 |
V, VA |
| Weight w/o holder: |
 |
9,1 |
5,3 |
9,2 |
kg |
| Dimensions: |
 |
750x300x260 |
500x200x200 |
750x300x260 |
mm |
| BZT-Registration: |
 |
G121 688F IF |
G117 067F IF |
G119 815F IF |
- |
|
|